OKAMA INFINITY NIGERIA LIMITED

+2348033463161, +2349016113535 & +2348079763565

  • Company Profile
  • About F-500 EA
  • Fire-Fighting & Safety
  • Oil & Gas Capabilities
  • Trainings & Awards
  • F-500 EA Live Demos
  • GB OIL-ONLY ABSORBENT
  • F-500 EA Webinars
  • Firefighting & Rescue
  • OKAMA FIREMEN IN ACTION
  • STAKE HOLDERS ENGAGEMENT
  • Chevron Agbami & NCDMB
  • More
    • Company Profile
    • About F-500 EA
    • Fire-Fighting & Safety
    • Oil & Gas Capabilities
    • Trainings & Awards
    • F-500 EA Live Demos
    • GB OIL-ONLY ABSORBENT
    • F-500 EA Webinars
    • Firefighting & Rescue
    • OKAMA FIREMEN IN ACTION
    • STAKE HOLDERS ENGAGEMENT
    • Chevron Agbami & NCDMB

+2348033463161, +2349016113535 & +2348079763565

     OKAMA INFINITY NIGERIA LIMITED
  • Company Profile
  • About F-500 EA
  • Fire-Fighting & Safety
  • Oil & Gas Capabilities
  • Trainings & Awards
  • F-500 EA Live Demos
  • GB OIL-ONLY ABSORBENT
  • F-500 EA Webinars
  • Firefighting & Rescue
  • OKAMA FIREMEN IN ACTION
  • STAKE HOLDERS ENGAGEMENT
  • Chevron Agbami & NCDMB

Maintenance Contract at AGBAMI FPSO - CHEVRON

Inspection, Testing, Maintenance and Certification services at Agbami FPSO - Chevron Nigeria

 - Physical inspection, examination, components assessment and safety limits testing and integrity assurance of  the equipment by the contractor as per the manufacturers recommendation and industry regulatory  requirements.  


- Inspection, testing and preventive maintenance and certification of the food preparation/Kitchen independent  f ire protection systems.  Duly certification of every piece of equipment inspected and maintained by industry regulatory requirements. 


- Ensure Annual Foam Concentrate Analysis meet regulatory requirements.  Foam concentrate testing evaluates  whether stored foam is in satisfactory condition and whether it remains compliant with international standards.  Annual testing is essential to ensure continuing integrity and is required by international standard NFPA 11:2021.  


 - Hydrotesting of Agbami FPSO Self Contained Breathing Apparatus (SCBA) bottles and fire extinguisher bottles.  Hydrostatic testing is the most common way to check a SCBA cylinder for leaks or flaws. The test involves filling the  SCBA cylinder with a liquid, usually water, which may be dyed to aid in visual lead detection, and pressurization of  SCBA cylinder to specified test pressure.  

-

Provision of Annual Foam Concentrate Analysis

Okama Infinity Nig LTD FIREFIGHTING EQUIPMENT MAINTENANCE

PREVENTIVE & CORRECTIVE MAINTENANCE OF FIREFIGHTING EQUIPMENT

 Okama Infinity Nigeria Limited maintenance of firefighting equipment on the Agbami FPSO is performed through a comprehensive, scheduled program of preventive and corrective maintenance guided by regulatory standards (e.g., IMO, NFPA, OISD) and manufacturer recommendations. This involves engaging both on-board crew with our specialized seasoned duly certified personnel.

SAFETY & OPEARTIONAL COMPLIANCE

 The maintenance program is crucial for ensuring the operational reliability of the Agbami FPSO, a major crude oil production facility owned by Chevron Nigeria.

 

  • Regulatory Compliance: The maintenance schedule and procedures must adhere to international maritime and oil and gas industry safety standards.
  • Scheduled Inspections: A multi-tiered inspection schedule (weekly, monthly, quarterly, annual, and five-year intervals) is implemented for all equipment.
  • Specialized Personnel: While some routine checks are performed by trained crew, more complex maintenance and annual inspections are handled by our certified technicians and specialists.
  • Documentation: Detailed maintenance logs and inspection reports are mandatory and must be kept on board for a specified period, often 10 years. 

FIREFIGHTING EQUIPMENT MAINTENANCE CONDUCTED

-  Physical inspection, examination, components assessment and safety limits testing and integrity assurance of  the equipment as per the manufacturers recommendation and industry regulatory  requirements.  


- Inspection, testing and preventive maintenance and certification of the food preparation/Kitchen independent  fire protection systems.  


- Duly certification of every piece of equipment inspected and maintained to attest to the job  and industry regulatory requirements. 


-   Annual Foam Concentrate Analysis to meet regulatory requirements.  


-  Hydrotesting of Agbami FPSO Self Contained Breathing Apparatus (SCBA) bottles and fire extinguisher bottles.  


-   Performance of all equipment   for the following;


*Portable fire extinguishers

*Wheel – unit extinguishers

*R-102 Agbami Kitchen fire suppression system

*Foam testing and Certification

*Fire Water System accessories

*Hose reels

*Fire Cabinets 

* Fire Monitors

* Fire Hydrants  


 

MAINTENANCE AND INSTALLATION OF FIREFIGHTING EQUIPMENT IN AG

Regulatory Compliance

Regulatory Compliance

Regulatory Compliance

 The maintenance schedule and procedures must adhere to international maritime and oil an.d gas industry safety standards..

Scheduled Inspections

Regulatory Compliance

Regulatory Compliance

 A multi-tiered inspection schedule (weekly, monthly, quarterly, annual, and five-year intervals) is implemented for all equipment. 

Specialized Personnel

Regulatory Compliance

Specialized Personnel

 While some routine checks are performed by trained crew, more complex maintenance and annual inspections are handled by our certified technicians and specialists. 

Show More

MaintenAnce of hose reels, fire monitors, valves, nozzles and other firefighting eguipment at agbami fpso (DEEP OFFSHORE)- chevron

    HYDROTESTING OF HOSES AT 300PSI FOR 5 MINUTES

    Hydrotesting at 300psi for 5 Minutes on various Hoses Exposing Leakages at Agbami FPSO Chevron  By Okama Infinity Nigeria Limited certified and trained technicians .

    REPLACEMENT OF NEW FIREMONITORS / HYDROTESTING OF HOSES AT AGBAMI FPSO CHEVRON

    Show More

    GASKET SETTING, LUBRICANT APPLICATIONS, BOLT TIGHTENING ON NEWLY INSTALLED FIRE MONITORS

      servicing of the dry chemical powder fire extinguishers

      At NCDMB Yenagoa, Bayelsa State

      At NCDMB Yenagoa, Bayelsa State

      At NCDMB Yenagoa, Bayelsa State

        

      The servicing process comprises of the following steps.


      1. Removing of the seals, safety pins, and discharge hoses for maintenance.

      2. Emptying of the DCP cylinder.

      3. Scaling of the fire extinguishers on the DCP refilling machine.

      4. Scaling of the DCP powder on the scaling machine.

      5. Maintenance/cleaning of the fire extinguisher stem and syphoned tube.

      6. Fixing of the discharge hose

      7. Engagement of the air compressor and clamping machine for pressurizing of the fire

      8. extinguishers with nitrogen gas.

      9. Washing, sun drying, and greasing of the fire extinguishers.

      10. Placement of the expiry date stickers and inspection tags.

      11. Redeployment of the fire extinguishers into their various cabinet in the NCT..

      Key Servicing Requirements

      At NCDMB Yenagoa, Bayelsa State

      At NCDMB Yenagoa, Bayelsa State

       Dry powder fire extinguishers require monthly visual inspections, annual professional servicing, and, according to guidelines from the National Fire Protection Association (NFPA), extended maintenance every 10 years, including pressure testing. Key maintenance involves checking for pressure gauge, ensuring no corrosion, and inverting/tapping the extinguisher to prevent powder clumping. National Fire Protection Association (NFPA) 


      3Key Servicing Requirements for Dry Powder Extinguishers

      • Monthly Checks: Ensure the extinguisher is accessible, the gauge shows in the green zone, the tamper seal is intact, and the nozzle is not blocked.
      • Preventative Maintenance (Every 2–3 Months): Turn the extinguisher upside down and tap it with a mallet to prevent the powder from compacting.
      • Annual Service (Professional): A qualified technician will inspect, test the pressure, check for damage, and check the weight.
      • Extended Service (Every 10 Years): Dry powder extinguishers typically require a full discharge, internal examination, and  a hydrostatic pressure test (every 10 years or as required by local regulations).
      • Recharging: Required immediately after any use, regardless of how small.

      GALAERY OF FIRE EXTINGUISHER CARRIED OUT AT THE NIGERIAN CIONTENT TOWERS, YENAGOA, BAYELSA STATE.

      01/24

      Servicing and Recertification: Dry Power Fire Extinguishers

       Servicing and Recertification of Dry Power Fire Extinguishers at NCDMB, Yenagoa, Bayelsa State. 

       Continuation of the Servicing and Recertification of Dry Power Fire Extinguishers at NCDMB 

      SUPPLY OF F-500 EA TO renaissance africa energy company limited IN PORT HARCOURT

      supply of f-500 ea to ncdmb bayelsa state


      Copyright © 2023 Okama Infinity Nigeria Limited - All Rights Reserved.

      Powered by

      F-500 EA THE FUTURE OF FIREFIGHTING

      Welcome! Check out our website for F-500 EA firefighting suppressant approved by NFPA for extinguishing all classes of fire effectively including lithium-ion battery fires.  Also excellent for Fire Rescue and Emergency Operations.

      Learn more